Feb. 23, 2011


Description

Surface casing failures on a group of relatively new wells prompted an investigation into the cause. External corrosion had occurred on the surface casing near the cement top between the casing and conductor and was caused by repetitive wetting events from water entering the unsealed annulus. Testing of water and cement samples indicate that the presence of oxygenated water and chemical salts that leach from the cement creates a low-resistance electrolyte resulting in an extremely corrosive environment. The oxygenated water in this environment creates an electro-chemical cell that corrodes the surface casing. Elevated casing temperatures and a high temperature gradient between the casing and the conductor accelerates the corrosion rate by creating a thermo-galvanic corrosion cell.

 

This presentation will:

  • Discuss the extent of shallow external casing corrosion observed in the field
  • Detail the mechanisms leading to the external corrosion
  • Detail the mechanical repair procedures used to return the wells to service
  • Discuss mitigation methods and remedial treatment to inhibit corrosion on new and existing wells.

This lecture illustrates that well barrier problems are not limited to being internal and deep in the well and require expensive (i.e., rig) methods to repair. Inexpensive repair approaches "outside the box" of traditional methods can be done safely, reduce risk and provide economic value for the company. The corrosion mechanism discussion should be applicable to most oil and gas operating areas around the globe.


Featured Speakers

Speaker Jerald Dethlefs

Well Integrity and Diagnostics Engineer
ConocoPhillips

Jerald C. Dethlefs is a Well Integrity and Diagnostics Engineer with ConocoPhillips in the Global Completions and Production Engineering Group in Houston, Texas. Dethlefs has 25 years of experience with well operations, intervention, production operations, and drilling. For the past 11 years, his focus …

Well Integrity and Diagnostics Engineer
ConocoPhillips


Jerald C. Dethlefs is a Well Integrity and Diagnostics Engineer with ConocoPhillips in the Global Completions and Production Engineering Group in Houston, Texas. Dethlefs has 25 years of experience with well operations, intervention, production operations, and drilling. For the past 11 years, his focus has been on well integrity issues including policy, diagnostics, best practices, program management and regulatory compliance. Dethlefs has a Bachelor of Science in General Engineering, a Master of Science in Civil Engineering and a Masters of Business Administration.


Full Description



Organizer

Mark Chapman


Date and Time

Wed, Feb. 23, 2011

11:30 a.m. - 1 p.m.
(GMT-0500) US/Central

Event has ended
View Our Refund and Cancellation Policy

Location

Greenspoint Club

16925 Northchase Drive
Houston, Texas 77060